Audit Sistem Pencahayaan dan Sistem Pendingin Ruangan dalam Upaya Efisiensi Energi Listrik di Gedung Perkantoran PT. Varia Usaha Beton Plant Tambakoso Waru.

Abidin, Moch Fajar (2021) Audit Sistem Pencahayaan dan Sistem Pendingin Ruangan dalam Upaya Efisiensi Energi Listrik di Gedung Perkantoran PT. Varia Usaha Beton Plant Tambakoso Waru. Undergraduate thesis, Universitas 17 Agustus 1945 Surabaya.

This is the latest version of this item.

[img] Text
ABSTRAK.pdf

Download (2MB)
[img] Text
BAB I.pdf
Restricted to Repository staff only

Download (351kB)
[img] Text
BAB II.pdf
Restricted to Repository staff only

Download (663kB)
[img] Text
BAB III.pdf
Restricted to Repository staff only

Download (564kB)
[img] Text
BAB IV.pdf
Restricted to Repository staff only

Download (493kB)
[img] Text
BAB V.pdf
Restricted to Repository staff only

Download (233kB)
[img] Text
DAFTAR PUSTAKA.pdf
Restricted to Repository staff only

Download (395kB)
[img] Text
LAMPIRAN.pdf

Download (1MB)
[img] Text
JURNAL.pdf

Download (284kB)
[img] Text
JURNAL HASIL TURNITIN.pdf

Download (1MB)

Abstract

An office building is one of the buildings that consumes high electrical energy. In general, the lighting system and air conditioning system are the factors causing the less efficient use of electrical energy in the PT. Varia Usaha Beton. Based on the Minister of Energy and Mineral Resources of the Republic of Indonesia No. 13 of 2012 concerning saving electricity consumption, it is necessary to manage electrical energy so that the intensity of electrical energy consumption can be managed properly and can be more efficient. In this study, an audit of the lighting system and air conditioning system was carried out and in this study used the energy audit method by calculating the Energy Consumption Intensity (IKE) value for the electrical energy efficiency process. From the calculation of the initial energy audit obtained the results of the IKE value at the head office building of PT. Varia Usaha Beton is 254.68 kWh/m2/year, this value exceeds the ASEAN-USAID standard of 240 kWh/m2/year. After energy conservation by replacing CFL lamps with LEDs in the lighting system and using inverter AC in the air conditioning system, the IKE value after conservation is 229.7 kWh/m2/year. This value is considered efficient because it is below the ASEAN-USAID standard.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Electrical Energy, Energy Audit, Energy Conservation, IKE
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > Program Studi Teknik Elektro
Depositing User: 1451700041 Moch. Fajar Abidin
Date Deposited: 03 Apr 2024 02:53
Last Modified: 03 Apr 2024 02:53
URI: http://repository.untag-sby.ac.id/id/eprint/11138

Available Versions of this Item

  • Audit Sistem Pencahayaan dan Sistem Pendingin Ruangan dalam Upaya Efisiensi Energi Listrik di Gedung Perkantoran PT. Varia Usaha Beton Plant Tambakoso Waru. (deposited 03 Apr 2024 02:53) [Currently Displayed]

Actions (login required)

View Item View Item