Analisa Jarak Lindung Lightning Arrester Terhadap Transformator Daya 60 MVA Di Gardu Induk 150 KV Surabaya Barat. (Lightning Arrester Protection Distance Analysis Against 60 MVA Power Transformer At 150 KV Substation West Surabaya).

Nasichin, Miftachun (2024) Analisa Jarak Lindung Lightning Arrester Terhadap Transformator Daya 60 MVA Di Gardu Induk 150 KV Surabaya Barat. (Lightning Arrester Protection Distance Analysis Against 60 MVA Power Transformer At 150 KV Substation West Surabaya). Undergraduate thesis, Universitas 17 Agustus 1945 Surabaya.

[img] Text (ABSTRAK)
ABSTRAK.pdf

Download (1MB)
[img] Text (BAB I)
BAB I.pdf
Restricted to Repository staff only

Download (116kB) | Request a copy
[img] Text (BAB II)
BAB II.pdf
Restricted to Repository staff only

Download (359kB) | Request a copy
[img] Text (BAB III)
BAB III.pdf
Restricted to Repository staff only

Download (386kB) | Request a copy
[img] Text (BAB IV)
BAB IV.pdf
Restricted to Repository staff only

Download (197kB) | Request a copy
[img] Text (BAB V)
BAB V.pdf
Restricted to Repository staff only

Download (226kB) | Request a copy
[img] Text (LAMPIRAN)
LAMPIRAN.pdf

Download (740kB)
[img] Text (JURNAL PUBLISH)
JURNAL.pdf

Download (744kB)
[img] Text (TURNITIN JURNAL)
JURNAL TURNITIN.pdf

Download (2MB)
[img] Text (LOA JURNAL)
LOA jurnal.pdf

Download (1MB)
[img] Other (Thumbnails conversion from text to thumbnail_lightbox)
lightbox.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_small)
small.jpg

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_lightbox)
lightbox.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_small)
small.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_lightbox)
lightbox.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_lightbox)
lightbox.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_lightbox)
lightbox.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_small)
small.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
Official URL: http://repository.untag-sby.ac.id/

Abstract

Dalam proses penyaluran energi listrik dari gardu induk ke konsumen sering kali terjadi gangguan, salah satunya adalah masalah gangguan tegangan lebih transien. Peralatan yang biasa digunakan untuk memproteksi gangguan akibat sambaran petir adalah lightning arrester. Penempatan lightning arrester dengan jarak tertentu dapat melindungi peralatan dari gangguan tegangan lebih gelombang surja hubung atau transien energi listrik. Jarak lightning arrester terhadap transformator daya 60 MVA yang terpasang adalah di gardu induk Surabaya Barat 150 kV sejauh 7,5 meter, sedangkan dari hasil perhitungan menyatakan bahwa jarak maksimal perlindungan optimum nya adalah 8,135 meter. Dengan begitu maka jarak lightning arrester terhadap transformator 60 MVA di Gardu Induk Surabaya Barat 150 kV masih berada dalam batasan jarak aman. Tingkat perlindungan lightning arrester terhadap transformator daya 60 MVA pada gardu induk Surabaya Barat 150 kV adalah 451,151 kV dengan factor perlindungan 30,5 % Dimana nilai ini lebih rendah dari Tingkat isolasi dasar yaitu 650 kV sehingga lightning arrester sudah memberikan perlindungan yang cukup baik.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Lightning Arrester, Surja petir, Transformator daya.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > Program Studi Teknik Elektro
Depositing User: 1452000044 Miftachun Nasichin
Date Deposited: 06 Apr 2001 17:21
Last Modified: 06 Apr 2001 17:21
URI: http://repository.untag-sby.ac.id/id/eprint/35104

Actions (login required)

View Item View Item