Rahmansyah, Muhammad Dhias (2026) Analisa Pengaruh Massa Refrigerant, Diameter Fan Kondensor dan Panjang Pipa Kapiler terhadap Performa Kulkas R-600a. (Analysis Of the Effect of Refrigerant Mass, Condensor Fan Diameter, And Capillary Pipe Length on the Performance of the R-600a Refrigerator). Undergraduate thesis, Universitas 17 Agustus 1945 Surabaya.
|
Text
ABSTRAK.pdf Download (1MB) | Preview |
|
|
Text (BAB I)
PENDAHULUAN.pdf Restricted to Repository staff only Download (397kB) | Request a copy |
||
|
Text (BAB II)
DASAR TEORI.pdf Restricted to Repository staff only Download (969kB) | Request a copy |
||
|
Text (BAB III)
METODE PENELITIAN.pdf Restricted to Repository staff only Download (872kB) | Request a copy |
||
|
Text (BAB IV)
ANALISA DATA.pdf Restricted to Repository staff only Download (4MB) | Request a copy |
||
|
Text (BAB V)
KESIMPULAN DAN SARAN.pdf Restricted to Repository staff only Download (399kB) | Request a copy |
||
|
Text
LAMPIRAN.pdf Download (1MB) | Preview |
|
|
Text
BUKTI SUBMIT MUHAMMAD DHIAS RAHMANSYAH 1422200087.pdf Download (135kB) | Preview |
|
|
Text
TURNITIN MUHAMMAD DHIAS RAHMANSYAH 1422200087.pdf Restricted to Repository staff only Download (2MB) | Request a copy |
Abstract
A refrigerator is a household cooling device used to maintain food quality by lowering and stabilizing temperature. The use of R-600a refrigerant has become an environmentally friendly alternative due to its zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP). However, the performance of a refrigeration system using R-600a is strongly affected by several parameters, including refrigerant mass, condenser fan diameter,and capillary tube length. This study aims to analyze the effect of these parameter variations on the performance of an R-600a refrigerator. The method used in this research was a laboratory experiment on a vapor compression refrigeration system operated under steady-state conditions. The collected data included pressure and temperature measurements at several main points of the system, which were then analyzed using thermodynamic principles and the pressure-enthalpy (P-h) diagram of R-600a refrigerant. The performance parameters evaluated in this study included refrigerant mass flow rate, compressor work, heat rejected by the condenser, heat absorbed by the evaporator, Heat Rejection Ratio (HRR), and Coefficient of Performance (COP). The results indicate that refrigerant mass, condenser fan diameter,and capillary tube length influence the performance of the refrigeration system. Increasing the refrigerant mass up to the optimum condition can improve cooling capacity and COP, while excessive refrigerant charge may reduce system efficiency. A suitable condenser fan diameter supports better heat rejection, while the proper selection of capillary tube helps optimize refrigerant flow and expansion pressure. Therefore, an appropriate combination of these parameters is required to achieve a more efficient performance of an R-600a refrigerator.
| Item Type: | Thesis (Undergraduate) |
|---|---|
| Uncontrolled Keywords: | R-600a, refrigerator, refrigerant mass, condenser fan, capillary tube, COP |
| Subjects: | T Technology > TJ Mechanical engineering and machinery |
| Divisions: | Fakultas Teknik > Program Studi Teknik Mesin |
| Depositing User: | 1422200087 Muhammad Dhias Rahmansyah |
| Date Deposited: | 24 Aug 2026 04:36 |
| Last Modified: | 24 Aug 2026 04:36 |
| URI: | http://repository.untag-sby.ac.id/id/eprint/47938 |