Analisa Ketidak Seimbangan Beban Pada Instalasi Tiga Fasa di PT Kosena Lestari Makmur. (Load Imbalance Analysis in Three-Phase Installation at PT Kosena Lestari Makmur).

Oematan, Siprianus (2023) Analisa Ketidak Seimbangan Beban Pada Instalasi Tiga Fasa di PT Kosena Lestari Makmur. (Load Imbalance Analysis in Three-Phase Installation at PT Kosena Lestari Makmur). Undergraduate thesis, Univeritas 17 Agustus 1945 Surabaya.

[img] Text
ABSTRAK.pdf

Download (3MB)
[img] Text
BAB I.pdf
Restricted to Repository staff only

Download (1MB)
[img] Text
BAB II.pdf
Restricted to Repository staff only

Download (20MB)
[img] Text
BAB III.pdf
Restricted to Repository staff only

Download (3MB)
[img] Text
BAB IV.pdf
Restricted to Repository staff only

Download (4MB)
[img] Text
BAB V.pdf
Restricted to Repository staff only

Download (544kB)
[img] Text
LAMPIRAN.pdf

Download (1MB)
[img] Text
JURNAL.pdf

Download (1MB)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_small)
small.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_lightbox)
lightbox.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_lightbox)
lightbox.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_lightbox)
lightbox.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_small)
small.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_lightbox)
lightbox.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_small)
small.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_preview)
preview.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)
[img] Other (Thumbnails conversion from text to thumbnail_small)
small.jpg

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Other (Generate index codes conversion from text to indexcodes)
indexcodes.txt

Download (0B)
[img] Text
JURNAL.pdf

Download (0B)

Abstract

PT Kosena Lestari Makmur merupakan Pabrik Olahan Makanan Jelly yang mengandalkan kualitas dan warna. Beban yang terpasang pada perusahaan ini terdiri dari beberapa jenis macam peralatan Elektronik dan mesin produksi yang terdiri dari mesin 1 fasa dan mesin 3 fasa sehingga jika tidak memperhatikan pembagian beban pada setiap fasa dengan baik sesuai standar operasional (SOP) tentunya dapat menimbulkan terjadinya keseimbangan beban yang terjadi menyebabkan losses daya, diantaranya losses akibat adanya arus netral pada penghantar netral traf. Penelitian tentang ketidakseimbangan beban ini dilakukan dengan mengukur arus (i) R,S,T,N masing-masing sebesar 130,119,120 (maksimum). Tegangan fasa-fasa (v) R-S, S-T, R-T masing-masing sebesar 385,397,383 (maksimum). Fasa netral (v) R-N, S-N, T-N masing-masing 232,223,337 pengukuran dilakukan pada panel MDP yang dilakukan selama 2 hari dalam kondisi beban maksimum dan kondisi beban minimum. Hasil analisis ini menunjukkan bahwa pada saat kondisi beban maksimum presentase pembebanan sebesar 0,92% dengan arus rata-rata sebesar 289 Ampere, dengan ketidakseimbangan yang terjadi sebesar -74% dan losses daya pada penghantar netral sebesar 0,086%. Sedangkan pada kondisi beban minimum presentase pembebanan sebesar 1,57% dengan arus rata-rata sebesar 183 Ampere, dengan ketidakseimbangan yang terjadi sebesar 2,7%. Kata Kunci : Ketidakseimbangan beban, arus netral, tigas fasa

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Load imbalance, neutral current, threes phase